Identification
Product Name: Oxygen (Gaseous)
Chemical formula: O
2
Stability
Stable. Supports combustion. Incompatible with organic materials,
phosphorus and many powdered metals.
Toxicology
Inhalation of high doses of oxygen may lead to hyperoxia.
Hazards Identification
- May cause breathing problem.
- Can cause central nervous system depression.
- May cause lung damage and throat soreness.
- May cause coughing and chest pain.
- High concentrations of oxygen causes cramps, dizziness, nausea,
ambylopia, hypothermia, respiration difficulties, and convulsions
capable of leading to death.
First Aid Measures
- Never use oil into the eyes without medical advice.
- Remove contaminated clothing
- Flush affected areas with lukewarm water.
- If irritation continues, seek medical advise.
- Wear protective clothing in recuing victims.
- Remove victim from affected are and allow him to inhale fresh air, as
soon as possible.
- Keep person warm and at rest.
Fire Fighting Measures
- Wear self-contained breathing musk and PPE.
- Wear protective gear.
- Cool fire exposed containers using water spray.
- Remove containers from affected area.
- Stop the flow of oxygen which is supporting the fire.
Accidental Release Measures
- Move away from the area
- Proper air ventilation should be ensured
- Remove ignition sources
- Stop release
- Do not enter basements and workpits where its accumulation is
hazardous.
Handling & Storage Handling
- Protect cylinders against physical damage.
- Ensure adequate ventilation.
- Avoid inhalation
- Do not work on a pressurized system.
- If there is a leak, close the upstream valve.
- Use storage containers suitable for storage and distribution of
Gaseous Oxygen.
- Store in cool, dry palce.
- Preferable store in fireproof area.
- Store away from heat and flammable sources.
- Store away from direct sunlight.
- Do not store oxygen cylinders near elevators, corridors or loading
docks.
- Do not drag, slide or roll oxygen cylinders.
- Do not drop cylinders or allow them to strike each other.
- Do not heat cylinder.
- Do not use oils or grease.
- Close main cylinder valve after use.